Hazards Related to Electric Cable Insulation in Case of Fire
The insulation of the electric cable is generally made up of rubber or plastic. The amount of smoke generated by the plastic in case of fire is dependent on factors like nature of plastic, type of additive used, flame of fire and ventilation arrangement. In general most plastics produce a very dense smoke when heated. In this article we will learn about the hazards related to electric cable insulation in case of fire.
Some plastic burns very clearly when subjected to heat and flame, producing very less smoke. If insulation used is of urethane foam it produces a very dense smoke and visibility in the room is lost in a minute. Some plastic contains Poly Vinyl Chloride (PVC) which produces hydro chloride gas as a product of combustion. This is a very deadly gas and has a pungent, irritating odor.
Rubber when used for insulation produces a dense black, oily smoke and has some toxic qualities. The most common gases produced during combustion of rubber are hydrogen sulphide and sulphur dioxide. These gases are both dangerous and can be fatal in certain cases.
Ways to Reduce these Hazards
The following steps should to taken as preventive measures
Cables having E.P.R (Ethylene Propylene Rubber) insulation with necessary sheathing of Polychloroprene or Chloro Sulphonated Polyethylene ( PCP or CSP) may be used to protect the insulation against fire.
G.i armor may be used to protect insulation from fire and needs to be earthed.
By using cables having high oxygen index number, the number allotted to material depending on minimum percentage of oxygen required to sustain combustion. If the material used is having oxygen index number 27, it means that minimum percentage of oxygen required to burn the material is 27 % which is well above the normal atmospheric oxygen percentage of 21 %. Thus, the insulation material will not catch fire.
Find out about insulation checking using megger meter.Â
Important Precautions for Installation of Electric Cables
- The cables and wiring external to the equipment must have flame retardant properties and should be installed in such a manner that it should not interfere with the original flame retarding properties.
- Cables and wirings for emergency equipments, lightings, communication and signal should be kept away from spaces like galley, laundries, machinery space of category A & other high risk areas.
- Special precautions are to be taken for cable installation in hazardous area as it might lead to explosion in case of electrical fault.
- Terminations and joints are to be made in such a manner that it should retain its original fire resisting properties.
- Avoid cable for damage and chafing during installation.
- Fireproof glands to be used in case of cable passing through the bulkhead as it would prevent fire from one compartment to other.
Disclaimer :
The information contained in this website is for general information purposes only. While we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the website or the information, products, services, or related graphics contained on the website for any purpose. Any reliance you place on such information is therefore strictly at your own risk.
In no event will we be liable for any loss or damage including without limitation, indirect or consequential loss or damage, or any loss or damage whatsoever arising from loss of data or profits arising out of, or in connection with, the use of this website.
Disclaimer :
The information contained in this website is for general information purposes only. While we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the website or the information, products, services, or related graphics contained on the website for any purpose. Any reliance you place on such information is therefore strictly at your own risk.
Do you have info to share with us ? Suggest a correction
Daily Maritime News, Straight To Your Inbox
Sign Up To Get Daily Newsletters
Join over 60k+ people who read our daily newsletters
By subscribing, you agree to our Privacy Policy and may receive occasional deal communications; you can unsubscribe anytime.
BE THE FIRST TO COMMENT