10 Safety Precautions To Take While Handling Inert Gas System On Ships

In November 2012, 5 officers on board an LPG tanker died when they “disassembled” a spectacle blind (also called spectacle flange or figure-8 blind used to prevent or start gas flow in a pipe system) without shutting off the inert gas supply, leading to their asphyxiation.

The investigation report said that six officers on board the LPG carrier fainted in the compressor room because of failure to shut off the inert gas supply and to ensure there was no inert gas in the pipe while removing the spectacle blind, leading to the release of inert gas into the compressor room causing asphyxiation.

Inert gas (IG) system is an integral part of cargo operations on tanker ships which must be handled with utmost care considering the hazardous effects of the inert gas on humans.

Officers handling the IG system must consider certain precautions to ensure their safety onboard ships.

inert gas system

1. Ensure Proper Maintenance of Inert Gas Safety Devices is Carried Out

Safety devices on IG systems are used to prevent the backflow of cargo gases to the machinery spaces.  It is important that along with the non-return valve, a water seal and a vent is also fitted on the deck main for additional safety.

Sometimes an additional water seal is fitted at the bottom of the scrubber. It is important that these devices are properly maintained at all times.

2. Ensure Adequate Oxygen Level 

Oxygen deficiency is extremely hazardous to the human body. It can not only damage the brain but can also lead to death easily.

In case of oxygen deficiency, the mind is likely to become apathetic and complacent and if escape is attempted at this stage, physical exertion will aggravate the weakness of the mind and body.

For this reason, it is necessary to ventilate the cargo tanks thoroughly to ensure that no pockets of oxygen deficiency remain and a steady reading of 21% is obtained at all times.

3. Ensure There are no Combustible Gases

An important point to note is that the inert gas does not affect the toxicity of hydrocarbon gases and thus the latter can be extremely dangerous (as it is flammable).

Gas freeing of tanks must be properly carried out to eliminate possible gas pockets. Any particular compartment must show a reading of Zero or 1% of the lower flammable limit (LFL) with a reliable combustible gas indicator.

4. Remove Toxic Components of Flue Gases

An approved combustible gas indicator should be used to measure the presence of flue gases in the tank. Flue gases contain sulphur dioxide, carbon monoxide and nitrogen which need to be properly measured during the gas freeing process.

After ventilation, the flue gas reading of the tank should be 1% or lower than the LFL along with an oxygen reading of 21%. Ventilation should be continued until a steady reading of 21% oxygen is obtained before entering.

fixed gas detection system

5. Check Tank Pressure 

Check the tanker pressure before opening any tank lids, ullage plugs or tank washing openings.  Inerted cargo tank pressure must be adequately reduced before opening any tank.

6. Prevent Air From Entering the System

In the event of an inert gas system failing to deliver the required quality and quantity of inert gas, or is not able to maintain a positive pressure in the cargo tanks, action must be taken immediately to prevent air from being drawn into the tanks.

All cargo and ballast discharge from inerted tanks must be stopped, the inert gas deck isolating valve closed, the vent valve between it and the gas pressure regulating valve (if provided) opened, and other immediate actions must be taken to repair the inert gas system.

7. Take Measures to Prevent Electrostatic Ignition 

The presence of hydrocarbons in the tanks can be dangerous. If the tank atmosphere contains flue gas, which has small particulate matter containing a small electrostatic charge, there is a possibility of an electrostatic ignition when the oxygen content of the tank rises due to the ingress of air.

Prevent any kind of ingress of air in the tanks.

8. Don’t Start Repair Work Without Gas Freeing

As Inert gas is asphyxiating, a person can quickly become unconscious even if the leakage of the gas has taken in the open air.

Extra precaution is thus required while doing any maintenance/repair work on the IG plant.

It is recommended that the I.G plant is completely gas freed before any work is started. Internal examination of any unit in the I.G. system should be done only after standard procedures for entry into enclosed spaces have been carried out.

9. Beware of Hydrogen Sulphide 

When the oxygen content is reduced during the operation of the I.G. system, pyrophoric deposits are formed in the tankers, especially in those carrying sour crude oil.

These deposits along with crude form hydrogen sulphide, which is highly toxic in nature. Pyrophors and hydrogen sulphide formed during a loaded passage can persist even during subsequent ballast passages if they are not properly removed.

10. Ensure Proper Functioning of  Blowers 

Generally on oil tankers, blowers are used for gas freeing and hence an air inlet (suction from the atmosphere) at the suction side of the blower with blanking arrangement must be provided.

At normal operation, blanking arrangement is to be secured. During gas freeing, it is to be opened and the air is to be supplied by the blower to the tanks.

Learn more about inerting and cargo operations in our ebooks.

1. The Ultimate Guide to Cargo Operation Equipment for Tankers

2. The Ultimate Guide to Cargo Operations for Tankers

Do you know any other important points to consider while handling inert gas on ships?

 

Disclaimer :
The information contained in this website is for general information purposes only. While we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the website or the information, products, services, or related graphics contained on the website for any purpose. Any reliance you place on such information is therefore strictly at your own risk.

In no event will we be liable for any loss or damage including without limitation, indirect or consequential loss or damage, or any loss or damage whatsoever arising from loss of data or profits arising out of, or in connection with, the use of this website.

Disclaimer :
The information contained in this website is for general information purposes only. While we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the website or the information, products, services, or related graphics contained on the website for any purpose. Any reliance you place on such information is therefore strictly at your own risk.


Do you have info to share with us ? Suggest a correction

By subscribing, you agree to our Privacy Policy and may receive occasional deal communications; you can unsubscribe anytime.

BE THE FIRST TO COMMENT

One Comment

  1. Dear sir!
    Can you explain for me difference P/V valve, P/V breather valve an P/V breaker valve. The follow i know p/v valve is fitted to a cargo tanks prevent over or under pressure, p/v breaker valve is fitted IG system while liqiud fill in the tanks , p/v breaker valve again prevent over or under pressurisation of a cargo tanks.
    I wait answer from you, Thank you sop much.