The speed of the marine engine is controlled by an instrument known as governor, which can be of – hydraulic, electro-hydraulic or electronic governor type.

The most famous types of governor used for both main engine and generator engine is the electro-hydraulic type marine governor. It’s because of this little instrument that the engine speed can be smoothly controlled from a remote space (bridge or engine control room).

The different components of a governor allows for a steady state speed control, along with achieving the required variation in the load.

marine engine

Following are the important parts of the governor:

– Synchronizer knob: This knob is used for controlling the speed of the engine with a single unit (Main engine) and controlling the load for engines with multiple unit (generator)

– Speed droop knob: The speed droop knob helps in creating the stability and also divides the load equally among multiple generator engines running parallel

– Load limit knob: This knob controls and limits the load on the engine by restricting the travel of the governor shaft, which is connected to the fuel shaft of the engine

– Synchronizer indication knob: This knob does not have any control function and it is used to show how many turns the synchronizer knob has rotated

When handling the electro-hydraulic governor of a marine engine, following things to be kept in mind:

1. Ensure the governor travel/ output shaft connected to the fuel shaft is provided with sufficient over-travel at each end of the terminal shaft. Failing to do so will either prevent it from giving more fuel at maximum fuel position or will shut down the prime mover when the shaft is in minimum fuel position

2. Ensure the oil level and quality is correctly maintained. The viscosity of the oil inside the governor at normal operating temperature should be in the range of 20 cst to 65cst. The recommended continuous operating temperature of the governor oil is 60 Deg C to 93 deg C.

governor

3. Never manually force the prime mover fuel linkage to increase the fuel without the first turning the load limit knob to maximum position of “10” else it will damage the governor’s internal parts

4. Ensure to apply as little compensation (through compensation needle provided for controlling the speed/load variation) as possible as higher compensation setting will lead to more fluctuation in speed with load change

5. For generator system running in parallel, set the speed droop at sufficiently high setting to avoid interchange of load between units while running

6. Synchronizer knob can be used to adjust the system frequency and to distribute the load between the units

7. Ensure to keep a check on the synchromotor for insulation and proper operation provided on the top of the governor, which transfers the remote signal to the governor for increasing or decreasing the engine speed

8. Ensure to check the tightness of the foundation bolts of the governor along with the tightness of the cable for synchro-motor. The governor is a high speed rotating instrument and excessive vibration with loose foundation will damage the interior parts

9. While testing the governor after overhauling, ensure all linkages are proper and oil level is upto the mark. Hold the output shaft with a serration wrench (monkey spanner) to manually control the speed in case the governor malfunctions

10. Never attempt to adjust the settings or the internal parts of the governor until you are thoroughly familiar with the proper procedure

It is very important that ship engineers are familiar with the planned maintenance of the governor. In no circumstances an engine with faulty governor should be operated as it may result in over-speeding of the engine and fatal accidents.

Over to you..

Any important points that can be added to this list?

Let’s know in the comments.

Do you have info to share with us ? Suggest a correction

Article Footer Banner
Article Footer Banner

Subscribe To Our Newsletters

By subscribing, you agree to our Privacy Policy and may receive occasional deal communications; you can unsubscribe anytime.

Web Stories

About Author

An ardent sailor and a techie, Anish Wankhede has voyaged on a number of ships as a marine engineer officer. He loves multitasking, networking, and troubleshooting. He is the one behind the unique creativity and aesthetics at Marine Insight.

6 Comments

  1. Hi sir we had faced overspeeding of engine since governor bearing seized and drive side tooth worn out all this found in findings. But for installation new governor we matched linkage length degree all as per manual my question is when initial start speed should be 300-400rpm to make this weather i need to adjust with speed setting or load limit knob to 50or 30%?

  2. Adjusting the speed setting or load limit knob to 50 or 30% may help to achieve an initial start speed of 300-400 RPM after a new governor has been installed, but it is important to refer to the manual for specific instructions on how to properly set the governor for optimal performance.

Leave a Reply

Your email address will not be published. Required fields are marked *